Electricity at Work Regulations This legislation places legal implications on employers to ensure the safety of electrical devices in the workplace. These Regulations impose health and safety requirements with respect to electricity at work. The Electricity at Work Regulations Made. 7th April Laid before Parliament. 25th April Coming into force. 1st April The Secretary of State.

Author: Dacage Zulugis
Country: Nicaragua
Language: English (Spanish)
Genre: Marketing
Published (Last): 27 June 2011
Pages: 379
PDF File Size: 3.47 Mb
ePub File Size: 10.93 Mb
ISBN: 695-8-32289-931-1
Downloads: 40169
Price: Free* [*Free Regsitration Required]
Uploader: Arami

A – switch to normal size A – switch to large size A – switch to larger size. Restriction of equipment in certain zones below ground. In these circumstances, inspectors are advised to recommend strongly that the consumer seeks assistance from an electricity PLC, an NICIEC contractor or other reputable contractor who can make the situation safe, ensure continuation of use by the consumer of the appliance or system, and provide a technical opinion on the condition of the installation.

No electrical equipment shall be put into use where its strength and capability may be exceeded in such a way as may give rise to danger.

A technical judgement by a competent person will often be needed to determine adequacy. Defence In any proceedings for an offence consisting of a contravention of regs 4 45, 8, 9, 10, 11, 12, 13, 14, 15 or 16, it shall be a defence for any person to prove that he took all reasonable steps and exercised all due diligence to avoid the commission of that offence.

Precautions for work on equipment made dead. Retrieved from ” https: In any proceedings for an offence consisting of a contravention of regs 4 45, 8, 9, 10, 11, 12, 13, 14, 15 or 16, it shall be a defence sawr any person to prove that he took all reasonable steps and exercised all due diligence to avoid the commission of that offence.

Regulation 6 states easr electrical equipment that may reasonably be foreseeable to be exposed to the following dangers must be constructed in such a way to protect or prevent so far as wawr reasonably practicable danger arising from such exposure:. In any proceedings for an offence consisting of a contravention of regulations 4 45, 8, 9, 10, 11, 12, 13, 14, 15, 16 or 25, it shall be a defence for any person to prove that he took all reasonable steps and exercised all due 189 to avoid the commission of that offence.

TOP Related Posts  BRUKSIZM TEDAVISI PDF

Operational guidance OCs home A film lighting circuit shall not be used unless—. Approval of certain equipment for use in safety-lamp mines. Introduction of battery-powered locomotives and vehicles into safety-lamp mines The hardware requirements are complemented by a group of Regulations stating principles of safe working practice.

Work on or near live conductors Health and Safety Executive. Persons on whom duties are 19899 by these Regulations. The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team.

11989 It does not cover machine malfunctions from electrical faults. The manager shall make suitable rules with respect to the Every year about 30 people die from electrical shock or electric burns at work. The Factories Act etc. Insulation, protection and placing of conductors. The Miscellaneous Mines Metrication Regulations Clearly, more knowledge is required of those involved in high voltage work compared to those doing volt test work.

The key requirements are adequate and relevant knowledge and experience, or an appropriate degree of supervision to allow persons to work safely and possibly to acquire those attributes.

Ask a solicitor eawrr now Ask My Question. Work on or near live conductors. This item of legislation is currently only available in its original format. More Resources Access essential accompanying documents and information for this legislation item from this tab.

OC /2: The electricity at work regulations

The purpose of these regulations is to require precautions to be taken against the risk of death or persoanl injury from electricity in work activities. The Electricity at Work Regulations EAW Regulations came into force on 1 April The purpose of these regulations is to require precautions to be taken against the risk of death or persoanl injury from electricity in work activities.

TOP Related Posts  CSA Z1000 PDF

All conductors in a system which may give rise to danger shall either—. Electrical equipment which may reasonably foreseeably be exposed to—. No person shall be engaged in any work activity on or so eaar any live conductor rawr than one suitably covered with insulating material so as to prevent danger that danger may arise unless—.

In court, FCG inspectors may be able to use such evidence to express a professional opinion as to the dangers which are present or likely to occur. This would include work in the vicinity of electrical equipment and insulated or uninsulated conductors.

Electricity at work – health and safety

Precautions for work on equipment made dead. Work carried out on or near a system, including both the 1899 of the system and the maintenance of the system, shall be carried out in such a manner as not to give rise, so far is reasonably practicable to danger.

The Mines Regulations came into force on 6 April and revoked regulations 17 to 28 and Schedule 1 of the Electricity at Work Regulations which previously applied only at mines. Electric shock notices Strength and capability of electrical equipment.

The Electricity at Work Regulations 1989

See also Electrical safety at work Maintaining electrical equipment safely Electricity e-Bulletin. You can visit our cookie eeawr page for more information. Lack of earthing can only be proved by measurement; simple observation is never adequate. There is no objection to occupiers displaying the new Regulations in placard form if they desire. Original As Enacted or Made: It is not comprehensive.